Spruce Drive

Full rebuild on an existing foundation · Erie, CO · Active

An approximately 2,300 ft² one-story home, rebuilt on its existing crawlspace foundation, with a mudroom addition.The goal is near-Passive House performance without certification. Targets: walls about R-40, roof about R-60, and an airtightness stretch goal of 1.0 ACH50 or better. Point 6 delivered envelope energy recommendations and a scenario model in June 2026, and a wall assembly comparison in August 2026.

WHAT POINT 6 WAS HIRED TO DO

Feasibility and design-phase energy model with report (designPH)

Envelope consulting and detail development, including air-sealing diagrams for the permit set

Heating and cooling loads (Manual J/D/S)

Material specification

CERTIFICATION GOAL

None. Near-Passive House performance; certification not pursued

Architect: SCD Architecture